TS2500Installation & User Guide496513 Issue A 1of26 TS2500NET LCD - Remote KeypadNETSTAR - Remote KeypadNETLED - Remote KeypadNETARM - Remote Keyp
Switch OFF ON1 XNODE circuits A &B enabledRemote keypad 1circuitsA&Benabled2 XNODE circuits C &D enabledRemote keypad 2circuitsA&Benab
TS900 NODE WiringTS900 NODE requires a 4 core cable forinterconnection, and up to 5 may be connected in a“daisy-chain”or“star”configurationtoanyonenet
Remote Keypads and TS700.LECsUp to 5 remote keypads or TS700.LECs can beconnectedonanynetwork. Thedevices maybewiredin a “daisy-chain” or “star” confi
Wiring Detection CircuitsAlldetectioncircuitsmaybewiredas“EndofLine”(EOL)OR “Double Pole” (DP). Both methods can be used onthesame equipment. Please r
TS2500TS2500 14 of 26 496513 Issue ASection Option DefaultSystem Timers2nd Entry delay 015 SecondsDouble Knock dly 010 SecondsAbort duration 010 Secon
TS2500496513 Issue A 15 of 26 TS2500Section Option DefaultTime SwitchesOn times 1,2 & 3 00:00Off times 1,2&3 00:00Timers operate on No daysTim
TS2500Log Event CodesTS2500 16 of 26 496513 Issue AEventDescription—- NO EVENT —- No event#### ACTIVATED Monitored circuit activated#,## LEC LOST Netw
TS2500496513 Issue A17 of 26 TS2500Event DescriptionCODE TAMPER Keypad locked out for 5 minutes due to invalid entry of passcodeCOMMS FAILED Plug-on d
TS2500TS250018 of 26 496513 Issue AEvent DescriptionPHONE LINE FAULT Telephone line fault detectedQUICK SET KEY # Quick set key A, B or C activatedQ.S
Key FunctionsEngineer’s Reset1. Key in engineer code default 1234. Displayshows “Engineer’s Menu 1”.2. Press ] display shows “Engineer Onsite”.This me
System OverviewSystem ArchitectureTS2500 2of26 496513 Issue ATS2500NOTE:Only one wiring method can beused on any one Network8 Zones 8 ZonesLEC8 LEC8Pr
Log Off EngineerSelecting this option willlog offall engineersand returnthe system to the “SYSTEM OPEN” condition.Reset User Code 1This option allows
Engineer’s Quick ReferenceTS2500496513 Issue A 21 of 26 TS2500Engineers Menu 1Hotkey Options1Program Panel Outputs1 = Panel Output 1 (relay)2 = Panel
TS2500TS2500 22 of 26 496513 Issue AHotkey Option1View CircuitsA/C = Scroll up and downENT = Toggle text / location2Set System TimeB = Toggle BST / GM
TS2500496513 Issue A 23 of 26 TS2500Hotkey Option1Auto-set TimersA = Timer 1 1 = Set Time 1B = Timer 2 2 = Set Time 2C = Timer 3 3 = Set Time 34 = Uns
TS2500Quick Reference User MenusTS2500 24 of 26 496513 Issue ASYSTEM OPEN18:10 Sun 01 JANEnter PasscodeUser Menu 2Rem service Opt.User Menu 2Start cal
Fault FindingTheTS2500 has various diagnostic functionstohelpyouinfault finding on the system. To access these functionsgo to Engineer’s Menu 3 option
TS2500 26 of 26 496513 Issue ATS2500This page intentionally left blank
IntroductionThe TS2500 intruder alarm control system has beendesigned to suit medium to large installation sites. TheTS2500 system can be expanded up
Expansion DevicesThere are several options for expanding the system:TS700 LECThe Local Expansion Card (LEC) provides twoprogrammable detection circuit
LED Remote KeypadPart No: NETLEDDisplay: 4 character seven segmentCurrent: 60mA (normal) 70mA (alarm)Zones: 2Output: Switched -ve @100mADimensions: 15
System InstallationTS2500TS2500 6of26 496513 Issue AOUTPUTMODULEPRINTERDIGI-MODEMCOMMS PORTFACTORYRESTARTJP5SYSTEMLEARNJP6BELL 12V (1 AMP)AUX 12V (1 A
Connection Terminals, Plugs & IndicatorsThe main PCB has the following connectors etc.1 Networks 1-8Data networks for connecting NODEs, remotekeyp
18 System Learn (JP6)If these pins are shorted whilst the system ispowered, the control panel will re-learn alldevices on all eight networks. If after
DC54/DC58 Plug-on DigicomsAplug-ondigitalcommunicator DC54orDC58 canbefitted inside the control panel to allow alarm statusinformation to be transferr