Menvier Security
Kenn Road Clevedon Avon BS21 6LH
Tel 01275 870078 Fax 01275 343453
E.Mail http//:www.menviersecurity.co.uk
TECHNICAL BULLETIN
SD1/001/93
SD1 CALL ACKNOWLEDGEMENT
Most of the queries we receive for the SD1 Speech Dialer relate to the acknowledgment
procedure This Technical Bulletin should clarify all aspects of the function, both for the end-
user and the installer.
At the end of its message the SD1 sends an audible “beep” which must be answered within 2
seconds using the tone generated by pressing the [8] button on a standard telephone. On
hearing the [8] tone the SD1 immediately sends a second “beep” which must also be
answered in the same way. If successful a multi-tone confirmation signal is heard , if not then
the message is repeated with the acknowledgment “beeps” again at the end.
POINTS TO NOTE:
1. The SD1 will not acknowledge signals from Pulse Dialing telephones or those with
short tones. Check all recipients phones by calling them and getting them to press
the [8] button . If a series of clicks is heard (or the tone cannot be sustained by
holding down the button) then a Tone Dial Simulator will be needed to acknowledge
the SD1 messages (see below for details).
2. No harm is done by not acknowledging the message as the unit simply repeats the
message 5 times and then aborts the call.
3. The procedure is fairly fast and should be practiced by all the recipients under test
conditions. The [8] button must be pressed within 2 seconds each “beep” and should
be held down for between ½ to 1 ½ seconds. If either tone is not “seen “ by the SD1
the message is repeated again.
TONE DIAL SIMULATORS
For the acknowledgment procedure the SD1 “looks” for any tone between 600Hz and 1400Hz.
This is supplied most reliably by the [8] button used for DTMF dialing although other buttons
may work if pressed accidentally. I the recipients phone cannot produce a suitable tone then a
Tone Dial Simulator musty be used. These are available from many high street electrical
stores and also from specialist suppliers such as RS (stock code 252-841) and Maplins (stock
code CK252C).