Remote Reset Number
The "Engineer Reset" option can be overridden by
the user, operating the "Remote Reset" facility. If
analarm is generated thesystemwill respond with
a four digit "seed" code which the user quotes to
the alarm company. The "seed" code is then
entered into a decoder and a unique "Remote
Reset" code is generated. This is passed back to
the user and, on entering the "Remote Reset"
code, the system will reset.
The "Remote Reset" code is generated using an
algorithm identified by a 3 digit number.
Alternative algorithms may be selected but these
must correspond to that used by the alarm
company otherwise the "Remote Reset" code will
be incorrect. The "Remote Reset" feature may be
disabled altogether by setting the number to
"000".
To program the remote reset number
proceed as follows:
1. Ensure that the engineer’s menu is selected,
then press [8] to select remote reset number.
2. Zone LEDs 1 to 3 will now light.
3. As the new remote reset number is entered
each LED will go out one by one. When all 3
digits have been entered, LEDs 1 to 3 will light
again and the new number must be
re-entered for confirmation.
4. Ahighpitchedtoneindicates the new number
was excepted, a low pitched tone indicates
the number was incorrectly entered and the
procedure must be repeated.
System Options
There are six system options which change the
functionality of the alarm system. The options are
as follows:
Bell Output
Thebelltriggeroutput [TRG-] can be programmed
as either:
SAB: When programmed as SAB the output will
switch to 0V on alarm.
SCB: When programmed as SCB the output
providesa0Vholdoff,whichisremovedonalarm.
Setting Mode
The system can be programmed to set using
ether:
Timed Exit: The system will set when the exit timer
has expired.
Final Exit: The system will set when the last
detector or door contact is activated during the
exit procedure. Note: When the system is part set
(HOME)thesystemwillalwayssetbytimedexitand
is silent.
Reset Authority
Theperson responsible for resetting full alarmscan
be programmed as either:
User: Following a full alarm the system can be
reset by the user.
Engineer: Following a full alarm the system can
only be reset by the engineer or Remote Reset (If
enabled).
System Re-arms
The system can be programmed to re-arm after
an alarm. The re-arm options are:
1 re-arm: When an alarm occurs, the internal
andexternal sounders areoperated for thelength
of the bell duration. At the end of this time the
alarm is silenced and the all zones are re-armed.
Any zones that are active will be automatically
isolated until they return to their healthy state. If an
alarm occurs from the same zone it will cause the
internal and external sounders to operate again,
at the end of the alarm the zone is "Locked-out"
andpreventedfromgeneratinganotheralarm.All
other healthy zones will re-arm and will only be
‘Locked-out’ when they have caused another
alarm.
3 Re-arms: Operates as above, but zones are
only "Locked-out" after the system has re-armed 3
times.
17
TS400/TS410 Installation Instructions Programming