Chart 2 - System Will Not Set
21
TS400/TS410 Installation Instructions Testing & Fault Finding
Enter 4 digit
engineer code and
then press 3 to select
walk test mode
Zone LED on and
Pulse Sounder.
No zone LED's on
and sounder is off.
Press to exit
Walk Test.
[0]
Press or
to part set
or full set the system.
[HOME]
[AWAY]
Remove control
panel cover and
disable the case
tamper.
Remove wiring from
AUX TAMPER
terminals and link
with a piece of wire
If the Tamper LED
remains lit, fit link
between TMP- and
H/O -
If Tamper LED goes
out there is an open
circuit within the
AUX TAMPER wiring.
If the Tamper LED
remains lit ,
disconnect the
battery.
If tamper LED goes
out the tamper on
the external siren is
open.
If the Tamper LED
remains lit, the
control panel is
faulty.
If the Tamper LED
goes out the
battery is faulty
Tamper LED on.
See Chart 1 on Zone
Faults
Deactivate all
detectors & contacts
(e.g. close doors
etc.)