PCB Layout
Bell Fuse
This 1 Amp fuse protects the supply to the external
sounder/bell.
Aux Fuse
This 1 Amp fuse protects the supply to devices
power from the auxiliary 12V terminals.
Speaker Volume R37
Cut R37 to reduce the volume of the extension
loudspeakers.
Factory Restart Pins
If these pins are shorted during power-up all
system programming data is restored to the
factory default values, see page 13 for defaults.
Home Inhibit Link
When the link is open the [ALM-] terminal activates
when an alarm occurs during a full or part set
condition. When the link is closed the [ALM-]
terminal activates only if an alarm occurs during a
full set condition.
1 - 5 Indicator LEDs
These red indicator LEDs indicate the alarm status
of zone 1 - 5. Note these are not fitted on the
TS410.
Unset Indicator LED
This green indicator LED is used to indicate the
status of the system set or unset. It also flashes
when the mains power is removed or when the
user selects the user program mode
Tamp Indicator LED
This red LED is used to indicate a system tamper
alarm, it also flashes when the engineer program
mode is selected. Note this is not fitted on the
TS410.
F/E Indicator LED
ThisredLEDisusedtoindicatethestatusofthefinal
exit zone. Note this is not fitted on the TS410.
8
System Installation TS400/TS410 Installation Instructions
A.C.
ALM
-
RST
-
TRG
-
STB
-
+H/O-
TMP
-
AUX
TAMPER
L/S
-
AUX 12V
+-
P. A .
ZONE 5
FIRE
ZONE 4
K'SW
ZONE 3
ACCESS
ZONE 2
ACCESS
ZONE 1
F/EXIT
Remote Keypad
Interface Connector
Keypad
(Not fitted on TS410)
Factory Restart Pins
Indicator LEDs
Home alarm
inhibit link
ut R
7toreduce
volume
(1AMP)
AUX 12V
Leads to
transformer
Tamper switch
Zone
connections
External
sounder
connections
Bell (1AMP)
123
456
789
HOME 0 AWAY
FACTORY
RESTART
VOLUME
R37
HOME ALM
INHIBIT
12
UNSET TAMP F/E
345
EXTERNAL BELL
Figure 3 TS400 & TS410 Connection Diagram